To achieve the ideal working performance of the electromagnetic belt iron remover, it is necessary to follow the correct procedures during operation. When the iron remover is working, the following three steps are crucial for the good operation of the equipment. Below is a specific analysis for everyone:
1. Before starting the electromagnetic belt type iron remover, each water pipe valve should be opened first to confirm whether the water nozzle is blocked. Look at the water pressure gauge and the displayed pressure must reach the required value.. Then start the oil pump. Before starting the oil pump, it is necessary to first open the cooling water pipe, open the valves of each part of the oil circuit, and then start the oil pump. After the oil pump is started, it is necessary to observe whether the oil pressure is normal and whether there is any oil leakage in various parts of the oil circuit to ensure normal circulation of the oil circuit.
2. Before using an electromagnetic belt type iron remover, a comprehensive inspection of the equipment should be conducted to determine the last shutdown time. If the equipment shuts down due to a malfunction, the malfunction must be resolved before considering startup. After checking and confirming that everything is normal, the operating equipment should be turned first. After rolling for one week, if the device rolls flexibly and does not get stuck, it indicates that there are no obstacles in the operating position. Otherwise, it is necessary to check and remove obstacles.
3. The current should be added after the main machine of the electromagnetic belt iron remover starts and operates normally. Be careful not to add it to the rated value at once, but gradually increase it to the rated current from small to large.